Chimney problems

Chimney Draft Problems: My Stove or Fireplace Will Not Draw

Chimney fire, or a room filling with smoke?Get everyone out and call 911 from outside.
Carbon monoxide alarm, or a smell of gas?Leave the building. Call 911 or your gas utility from outside.
Fire out, but it happened?Do not use the appliance again until a Level 2 inspection.

Draft is the pressure difference that pulls combustion products up a chimney. Warm flue gases rising is what makes that possible. Failures split into two kinds and they are worth separating, since they mean different things. A sudden loss of draft in an appliance that always worked is a blockage until proven otherwise: a nest, a collapsed liner, a blocked cap or spark screen, or snow and ice at the termination. A stop-using-it situation, because whatever is not going up the chimney is coming into the room. A chronic weak draft that has always been there is a design problem: a flue oversized for the appliance, a cold exterior chimney, a termination too low relative to the roof, or a house too tight to supply combustion air. Chronic problems are fixable, but not on the evening you notice them.

Before you call

Checks you can do safely

  • Distinguish sudden from chronic: it changes what is likely
  • Confirm the damper is fully open
  • Turn off dryers, range hoods and bath fans and try again
  • Crack a window and see whether behaviour changes
  • Check the cap and termination from the ground for an obvious blockage
  • Note whether it correlates with wind, temperature or mild weather
  • Do not keep burning to see whether it improves
Two chimneys side by side serving the same stove. In the correctly sized flue the exhaust stays warm, moves quickly and leaves the top. In the oversized flue the same exhaust expands, slows and cools, condensing on the flue wall as creosote.Correctly sizedWarm, fast, leaves the topOversizedExpands, slows, cools, condensessameapplianceboth sidescreosote
Draft depends on flue gases staying warm. A flue larger than the appliance needs lets them cool and condense.

No draft: causes in the order worth checking

Stop using the appliance until it has been inspected

Possible causeRank
A blockage: nest, debris, collapsed liner, blocked cap or spark screenMost common
Snow or ice at the termination, a recurring Vermont cause2
A cold flue that has not been warmed before lighting3
A flue oversized for the appliance, so gases cool and slow4
An exterior chimney that never warms enough to establish draft5
A termination too low relative to the roof or nearby obstructions6
House negative pressure from fans, a range hood or a furnace7
Heavy creosote reducing the effective flue area8
Often confused with this

Related problems

If what you have is not no draft after all, the full list of chimney problems is grouped by urgency, and the service triage tool takes a symptom and returns the stop condition and the service it maps to.

No draft

Common questions about no draft

It worked yesterday and today it will not draw at all.+

That pattern points hard at a blockage, and it is the version that means stop using the appliance now. A nest, a collapsed tile, a blocked spark screen or snow and ice at the top will all do it, and none of them clear themselves.

Why does a cold chimney not draw?+

Because draft comes from the temperature difference between the flue gases and the outside air. A cold flue full of dense cold air has to be displaced before the chimney will pull, so warming it before lighting makes such a difference.

Why is it worse on mild days?+

Less temperature difference between inside and outside means less draft. A mild damp day in shoulder season is the hardest condition for a marginal chimney, and it is often when people first notice a problem that was always there.

How can a flue be too big?+

Draft depends on keeping gases warm, and a large flue lets them expand, slow and cool. A modern efficient stove vented into a fireplace flue is the classic case. The appliance produces less hot exhaust than the flue was designed around, so it never establishes a proper pull.

What does house negative pressure do?+

It makes the chimney the path of least resistance for air coming into the house, which reverses it. Turning off the dryer, range hood and bath fans and seeing whether the behaviour changes is a fast and reliable test.

Is my chimney tall enough?+

There is a recognised relationship between the flue termination and the roof around it, and a stack terminated too low relative to its own roof, or shadowed by a taller structure or trees, will draw poorly no matter what is done inside the flue.

Could snow really block it?+

Yes, and it is a regular Vermont cause. Drifting snow blocks low direct-vent terminations, and ice builds on caps and spark screens. Both interfere with an appliance's ability to breathe, and on a sealed appliance that is a combustion-safety matter.

Would a taller chimney or a different cap help?+

Sometimes, and it depends on the diagnosis. Extending a short flue, or fitting a cap designed for downdraft conditions, are legitimate remedies for specific causes. Fitting one hopefully, without establishing the cause, is how people end up with two problems.

Can heavy creosote cause poor draft?+

Yes, by reducing the effective diameter of the flue. One of the easier causes to rule in or out, since a sweep either changes the behaviour or proves the problem is elsewhere.

Will an insulated liner fix a cold chimney?+

The usual remedy and it broadly works, since it keeps flue gases warm enough to establish and hold draft while sizing the flue correctly for the appliance. It also reduces creosote, since the two problems have the same root.

Is poor draft dangerous or just annoying?+

A safety matter. Whatever is not going up the chimney is entering the room, and that includes carbon monoxide, which you cannot smell. A chronically poor-drawing appliance is not something to work around indefinitely.

What will an inspection establish?+

Whether there is a blockage, what the flue size is relative to the appliance, the condition of the liner, the termination height and configuration, and whether the house pressure conditions are contributing. The last one gets missed most often.